QModbusServer 类

The QModbusServer class is the interface to receive and process Modbus requests. 更多...

头: #include <QModbusServer>
qmake: QT += serialbus
Since: Qt 5.8
继承: QModbusDevice
继承者: QModbusRtuSerialSlave and QModbusTcpServer

公共类型

enum Option { DiagnosticRegister, ExceptionStatusOffset, DeviceBusy, AsciiInputDelimiter, ..., UserOption }

公共函数

QModbusServer (QObject * parent = nullptr)
bool data (QModbusDataUnit * newData ) const
bool data (QModbusDataUnit::RegisterType table , quint16 address , quint16 * data ) const
virtual bool processesBroadcast () const
int serverAddress () const
bool setData (const QModbusDataUnit & newData )
bool setData (QModbusDataUnit::RegisterType table , quint16 address , quint16 data )
virtual bool setMap (const QModbusDataUnitMap & map )
void setServerAddress (int serverAddress )
virtual bool setValue (int option , const QVariant & newValue )
virtual QVariant value (int option ) const

信号

void dataWritten (QModbusDataUnit::RegisterType register , int address , int size )

保护函数

virtual QModbusResponse processPrivateRequest (const QModbusPdu & request )
virtual QModbusResponse processRequest (const QModbusPdu & request )
virtual bool readData (QModbusDataUnit * newData ) const
virtual bool writeData (const QModbusDataUnit & newData )

额外继承成员

详细描述

The QModbusServer class is the interface to receive and process Modbus requests.

Modbus networks can have multiple Modbus servers. Modbus Servers are read/written by a Modbus client represented by QModbusClient . QModbusServer communicates with a Modbus backend, providing users with a convenient API.

成员类型文档编制

enum QModbusServer:: Option

Each Modbus server has a set of values associated with it, each with its own option.

The general purpose options (and the associated types) are:

常量 描述
QModbusServer::DiagnosticRegister 0 The diagnostic register of the server. quint16
QModbusServer::ExceptionStatusOffset 1 The exception status byte offset of the server. quint16
QModbusServer::DeviceBusy 2 Flag to signal the server is engaged in processing a long-duration program command. quint16
QModbusServer::AsciiInputDelimiter 3 The Modbus ASCII end of message delimiter. char
QModbusServer::ListenOnlyMode 4 Flag to set listen only mode of the server. This function is typically supported only by Modbus serial devices. bool
QModbusServer::ServerIdentifier 5 The identifier of the server, not the server address. quint8
QModbusServer::RunIndicatorStatus 6 The run indicator of the server. quint8
QModbusServer::AdditionalData 7 The additional data of the server. QByteArray
QModbusServer::DeviceIdentification 8 The physical and functional description of the server. QModbusDeviceIdentification

用户选项:

常量 描述
QModbusServer::UserOption 0x100 The first option that can be used for user-specific purposes.

For user options, it is up to the developer to decide which types to use and ensure that components use the correct types when accessing and setting values.

成员函数文档编制

QModbusServer:: QModbusServer ( QObject * parent = nullptr)

构造 Modbus 服务器采用指定 parent .

bool QModbusServer:: data ( QModbusDataUnit * newData ) const

Returns the values in the register range given by newData .

newData must provide a valid register type, start address and valueCount. The returned newData will contain the register values associated with the given range.

newData contains a valid register type but a negative start address the entire register map is returned and newData appropriately sized.

另请参阅 setData ().

bool QModbusServer:: data ( QModbusDataUnit::RegisterType table , quint16 address , quint16 * data ) const

Reads data stored in the Modbus server. A Modbus server has four tables ( table ) and each have a unique address field, which is used to read data from the desired field. See QModbusDataUnit::RegisterType for more information about the different tables. Returns false if address is outside of the map range or the register type is not even defined.

另请参阅 QModbusDataUnit::RegisterType and setData ().

[signal] void QModbusServer:: dataWritten ( QModbusDataUnit::RegisterType register , int address , int size )

This signal is emitted when a Modbus client has written one or more fields of data to the Modbus server. The signal contains information about the fields that were written:

  • register type that was written,
  • address of the first field that was written,
  • and size of consecutive fields that were written starting from address .

The signal is not emitted when the to-be-written fields have not changed due to no change in value.

[virtual protected] QModbusResponse QModbusServer:: processPrivateRequest (const QModbusPdu & request )

This function should be implemented by custom Modbus servers. It is called by processRequest () if the given request is not a standard Modbus request.

Overwriting this function allows handling of additional function codes and subfunction-codes not specified in the Modbus Application Protocol Specification 1.1b. Reimplementations should call this function again to ensure an exception response is returned for all unknown function codes the custom Modbus implementation does not handle.

此默认实现返回 QModbusExceptionResponse 采用 request function code and error code set to illegal function.

另请参阅 processRequest ().

[virtual protected] QModbusResponse QModbusServer:: processRequest (const QModbusPdu & request )

Processes a Modbus client request and returns a Modbus response. This function returns a QModbusResponse or QModbusExceptionResponse depending on the nature of the request.

The default implementation of this function handles all standard Modbus function codes as defined by the Modbus Application Protocol Specification 1.1b. All other Modbus function codes not included in the specification are forwarded to processPrivateRequest ().

The default handling of the standard Modbus function code requests can be overwritten by reimplementing this function. The override must handle the request type in question and return the appropriate QModbusResponse . A common reason might be to filter out function code requests for data values to limit read/write access and function codes not desired in particular implementations such as serial line diagnostics on ethernet or Modbus Plus transport layers. Every other request type should be forwarded to this default implementation.

注意: This function should not be overridden to provide a custom implementation for non-standard Modbus request types.

另请参阅 processPrivateRequest ().

[虚拟] bool QModbusServer:: processesBroadcast () const

Subclasses should implement this function if the transport layer shall handle broadcasts. The implementation then should return true if the currently processed request is a broadcast request; otherwise false . The default implementation returns always false .

注意: The return value of this function only makes sense from within processRequest () 或 processPrivateRequest (), otherwise it can only tell that the last request processed was a broadcast request.

[virtual protected] bool QModbusServer:: readData ( QModbusDataUnit * newData ) const

Reads the values in the register range given by newData and writes the data back to newData 。返回 true 当成功时或 false if newData is 0 newData range is outside of the map range or the registerType() does not exist.

注意: Sub-classes that implement reading from a different backing store then default one, also need to implement setMap () 和 writeData ().

另请参阅 setMap () 和 writeData ().

int QModbusServer:: serverAddress () const

Returns the address of this Mobus server instance.

另请参阅 setServerAddress ().

bool QModbusServer:: setData (const QModbusDataUnit & newData )

写入 newData to the Modbus server map. Returns false newData range is outside of the map range.

If the call was successful the dataWritten () signal is emitted. Note that the signal is not emitted when the addressed register has not changed. This may happen when newData contains exactly the same values as the register already. Nevertheless this function returns true in such cases.

另请参阅 data ().

bool QModbusServer:: setData ( QModbusDataUnit::RegisterType table , quint16 address , quint16 data )

Writes data to the Modbus server. A Modbus server has four tables ( table ) and each have a unique address field, which is used to write data to the desired field. Returns false if address outside of the map range.

If the call was successful the dataWritten () signal is emitted. Note that the signal is not emitted when data has not changed. Nevertheless this function returns true in such cases.

另请参阅 QModbusDataUnit::RegisterType , data (),和 dataWritten ().

[虚拟] bool QModbusServer:: setMap (const QModbusDataUnitMap & map )

Sets the registered map structure for requests from other ModBus clients to map . The register values are initialized with zero. Returns true 当成功时;否则 false .

If this function is not called before connecting, a default register with zero entries is setup.

注意: Calling this function discards any register value that was previously set.

void QModbusServer:: setServerAddress ( int serverAddress )

Sets the address for this Modbus server instance to serverAddress .

另请参阅 serverAddress ().

[虚拟] bool QModbusServer:: setValue ( int option , const QVariant & newValue )

设置 newValue for option 并返回 true 当成功时; false 否则。

注意: 若选项的关联类型为 quint8 or quint16 and the type of newValue is larger, the data will be truncated or conversation will fail.

Key 描述
QModbusServer::DiagnosticRegister Sets the diagnostic register of the server in a device specific encoding to newValue . The default value preset is 0x0000 . The bit values of the register need device specific documentation.
QModbusServer::ExceptionStatusOffset Sets the exception status byte offset of the server to newValue which is the absolute offset address in the coils (0x register). Modbus register table starting with 0x0000h . The default value preset is 0x0000 , using the exception status coils similar to Modicon 984 CPUs (coils 1-8).

函数返回 true if the coils register contains the 8 bits required for storing and retrieving the status coils, otherwise false .

QModbusServer::DeviceBusy Sets a flag that signals that the server is engaged in processing a long-duration program command. Valid values are 0x0000 (not busy) and 0xffff (busy). The default value preset is 0x0000 .
QModbusServer::AsciiInputDelimiter The newValue becomes the end of message delimiter for future Modbus ASCII messages. The default value preset is \n .
QModbusServer::ListenOnlyMode Ss the server's listen only state to newValue . If listen only mode is set to true , messages are monitored but no response will be sent. The default value preset is false .
QModbusServer::ServerIdentifier Sets the server's manufacturer identifier to newValue . Possible values are in the range of 0x00 to 0xff. The default value preset is 0x0a .
QModbusServer::RunIndicatorStatus Sets the servers' run indicator status to newValue . This data is used as addendum by the QModbusPdu::ReportServerId function code. Valid values are 0x00 (OFF) and 0xff (ON). The default value preset is 0xff (ON).
QModbusServer::AdditionalData Sets the server's additional data to newValue . This data is used as addendum by the QModbusPdu::ReportServerId function code. The maximum data size cannot exceed 249 bytes to match response message size restrictions. The default value preset is Qt Modbus Server .
QModbusServer::DeviceIdentification Sets the server's physical and functional description. By default there is no additional device identification data set.
QModbusServer::UserOption Sets the value of a user option to newValue .

注意: For user options, it is up to the developer to decide which types to use and ensure that components use the correct types when accessing and setting values.

另请参阅 value ().

[虚拟] QVariant QModbusServer:: value ( int option ) const

Returns the value for option or an invalid QVariant if the option is not set.

选项 描述
QModbusServer::DiagnosticRegister Returns the diagnostic register value of the server. The diagnostic register contains device specific contents where each bit has a specific meaning.
QModbusServer::ExceptionStatusOffset Returns the offset address of the exception status byte location in the coils register.
QModbusServer::DeviceBusy Returns a flag that signals if the server is engaged in processing a long-duration program command.
QModbusServer::AsciiInputDelimiter Returns a end of message delimiter of Modbus ASCII messages.
QModbusServer::ListenOnlyMode Returns the server's listen only state. Messages are monitored but no response will be sent.
QModbusServer::ServerIdentifier Returns the server manufacturer's identifier code. This can be an arbitrary value in the range of 0x00 to 0xff.
QModbusServer::RunIndicatorStatus Returns the server's run indicator status. This data is used as addendum by the QModbusPdu::ReportServerId function code.
QModbusServer::AdditionalData Returns the server's additional data. This data is used as addendum by the QModbusPdu::ReportServerId function code.
QModbusServer::DeviceIdentification Returns the server's physical and functional description.
QModbusServer::UserOption

Returns the value of a user option.

注意: For user options, it is up to the developer to decide which types to use and ensure that components use the correct types when accessing and setting values.

另请参阅 setValue ().

[virtual protected] bool QModbusServer:: writeData (const QModbusDataUnit & newData )

写入 newData to the Modbus server map. Returns true 当成功时,或 false newData range is outside of the map range or the registerType() does not exist.

注意: Sub-classes that implement writing to a different backing store then default one, also need to implement setMap () 和 readData ()。 dataWritten () signal needs to be emitted from within the functions implementation as well.

另请参阅 setMap (), readData (),和 dataWritten ().